1 config: remote, 1 config: remote ( local, 2 config: remote ( serial – Mocomtech CDM-QX User Manual
Page 76

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®
Revision 7
Front Panel Operation
MN/CDMQX.IOM
5–10
5.4.1
CONFIG: Remote
 Remote Control Entry: Local 
 Serial Ethernet (◄ ►,ENT) 
Select Local, Serial, or Ethernet using the
◄ ►
arrow keys, then press
ENTER
.
5.4.1.1 CONFIG: Remote
Æ Local
If CONFIG: Remote Æ Local is selected, remote control is disabled, although remote monitoring 
is still possible. 
5.4.1.2 CONFIG: Remote
Æ Serial
 Remote Serial Config: 
 Interface Baudrate (◄ ►,ENT) 
Select Interface or Baudrate using the
◄ ►
arrow keys, then press
ENTER
.
CONFIG: Remote
Æ Serial Æ Interface
 M&C Serial Interface: RS232 
 RS485-2W RS485-4W (◄ ►,ENT 
From the Interface submenu, the user is further prompted to enter the bus address. Select 
RS232, RS485-2W (2-wire), or RS485-4W (4-wire) using the 
◄ ► arrow keys, then press
ENTER
.
CONFIG: Remote
Æ Serial Æ Interface Æ RS232
 In RS-232 Mode, Serial Bus 
 Base Address is fixed @ 0000 
Note that the bus base address in RS-232 mode is fixed and cannot be edited.
CONFIG: Remote
Æ Serial Æ Interface Æ RS485(-2W, -4W)
 Edit RS-485 Serial Bus Base 
 Address: 0245 (◄ ►,▲▼,ENT) 
If either RS-485 mode is selected, edit the RS-485 bus address of this unit by first 
selecting the digit to be edited using the
ef
arrow keys, then change the value of the
digit to be edited by using the dc arrow keys. The valid range of addresses is from 1 to 
9999. Press ENTER when done. 
CONFIG: Remote
Æ Serial Æ Baudrate
 M&C Serial Bus Baud Rate: 
 19200 Baud (▲ ▼,ENT) 
Using the cd arrow keys, edit the baudrate of the remote control bus connected locally to 
the M&C computer. Values of 2400, 4800, 9600, 19200, 38400, and 57600 baud are 