CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision
7
Appendix C
MN/CDMQX.IOM
C–26
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Faults and Status
N/A
12 bytes
Query only.
Unit returns the current highest-prority fault and status codes for the Unit (hardware), TX
Traffic, RX Traffic, and ODU in the form abcdef, where:
a=Unit Faults:
0=No Faults
1=Power Supply Fault, +5 volts
2=Power Supply Fault, +12 volts
3=Power Supply Fault, -5 volts
4=Power Supply Fault, +23 volts
5=Power Supply Fault, -12 volts
9=Ref PLL Lock
F=EEPROM Checksum error
6,7,8,A,B,C,D,E are reserved for future expansion
bb=fault codes for Slot#1 can be Tx or Rx Traffic status
cc=fault codes for Slot#2 can be Tx or Rx Traffic status
dd=fault codes for Slot#3 can be Tx or Rx Traffic status
ee=fault codes for Slot#4 can be Tx or Rx Traffic status
TX Traffic status:
00=TX Traffic OK
01=No Clock from Terrestrial Interface
03=TX FIFO Slip
06=TX Synthesizer Lock
07=AUPC Upper Limit Reached
09=AIS Detected on Incoming Data
0B=Bipolar violation on G.703 Interface
0F=TX EEPROM Checksum Error
12=Power supply fault, +5 volts
13=Power supply fault, -5 volts
14=Power supply fault, +12 volts
15=Power supply fault, -12 volts
16=Power supply fault, +23 volts
the rests are reserved for future expansion
RX Traffic status:
0=RX Traffic OK
1=Demodulator Unlocked
3=AGC Alarm – signal out of range
5=RS Frame SYNC alarm
7=EDMAC Frame SYNC alarm
8=RX 1
st
LO Synthesizer Lock
9=RX 2
nd
LO Synthesizer Lock
A=Buffer Under
B=Buffer Overflow
D=Eb/No alarm
E=AIS detected on incoming data
F=RX EEPROM checksum error
10=Demod FPGA not programmed
11=Turbo FPGA not programmed
12=Power supply fault, +5 volts
13=Power supply fault, -5 volts
14=Power supply fault, +12 volts
15=Power supply fault, -12 volts
16=Power supply fault, +23 volts
17=QDI Deframer Unlocked
18=Buffer Clock Activity
the rests are reserved for future expansion
f=ODU status: (for CDM-QxL L-Band unit only)
0=No ODU Faults
1=BUC PLL
3=BUC Current
5=BUC Voltage
7=LNB Current, 9=LNB Voltage, B=BUC Temperature, D=BUC Checksum
N/A FLT?
FLT=abbccddeefgh
(see Description of Arguments)
g=Change in fault status since last
poll.
h=Change in unit configuration
since last poll