Mocomtech CDM-QX User Manual
Page 227

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision
7
Appendix C
MN/CDMQX.IOM
C–9
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
TX Power
Level
TPL=
4 bytes
Command or Query.
TX Output power level between -5 and –25 dBm (minus sign
assumed)
Example: TPL=13.4
(Command not valid in AUPC mode)
Note: When output power level is enabled: Power level
configuration is not allowed. Response will be TPL*. The response
to the query TPL? Will be the adjusted levelled value.
TPL=
TPL?
TPL*
TPL#
TPL$
TPL^
TPL@
TPL? TPL=xx.x
(see Description of
Arguments)
TX Reed-
Solomon (n,
k) values
TRS=
1 byte
Command or Query.
TX Reed-Solomon (n, k) values in the form x, where:
0=Unframed closed network (220,200)
1=EFD closed network (225,205)
2=IESS-310 compatible operation (219,201)
3=EDMAC mode, closed (200,180) – EDMAC only
Notes:
1. Selection is valid only when TFT=2 or TFT=5.
2. For D&I++, selection 0,1, and 2 are supported.
TRS=
TRS?
TRS*
TRS#
TRS$
TRS^
TRS@
TRS? TRS=x
(see Description of
Arguments)
TX
Scrambler
TSC=
1 byte, value
of 0, 1, 2
Command or Query.
Tx Scrambler state in the form x, where:
0=Off
1=ON (Default scrambler type)
2=ON IESS-315 (Turbo Only)
Example: TSC=1 (Scrambler one)
TSC=
TSC?
TSC*
TSC#
TSC$
TSC^
TSC@
TSC? TSC=x
(see Description of
Arguments)
TX Spectrum
Invert
TSI=
1 byte, value
of 0, 1
Command or Query.
TX Spectrum Invert Selection in the form x, where:
0=Normal
1=TX Spectrum Invert
Example: TSI=0 (Normal)
TSI=
TSI?
TSI*
TSI#
TSI$
TSI^
TSI@
TSI? TSI=x
(see Description of
Arguments)
TX roll-off
(alpha) factor
TXA=
1 byte
Command or Query.
Tx roll-off (alpha) factor in the form x, where:
0=20%
1=35% (default)
TXA=
TXA?
TXA*
TXA#
TXA$
TXA^
TXA@
TXA TXA=x
(see Description of
Arguments)