P.7 restrainable errors, P.7.1 asi_async_fault_status (asi_afsr), Restrainable errors 174 – FUJITSU Implementation Supplement Fujitsu SPARC64 V User Manual
Page 185: Asi_async_fault_status (asi_afsr) 174, P.7.1

174
SPARC JPS1 Implementation Supplement: Fujitsu SPARC64 V • Release 1.0, 1 July 2002
P.7
Restrainable Errors
This section describes the registers—
ASI_ASYNC_FAULT_STATUS
,
ASI_ASYNC_FAULT_ADDR_D1
, and
ASI_ASYNC_FAULT_ADDR_U2
—that define the
restrainable errors and explains how software handles these errors.
P.7.1
ASI_ASYNC_FAULT_STATUS (ASI_AFSR)
The
ASI_ASYNC_FAULT_STATUS
register holds the detected restrainable error
describes the fields of this register. In the table, the prefixes in
the name field have the following meaning:
■
DG_
Degradation error
■
CE_
Correctable Error
■
UE_
Uncorrectable Error
Notes about the
Prio_
xx columns in
■
Prio_D1
column
— Indicates the
ASI_AFAR_D1
recording priority for each error
shown in
row as follows:
■
If the
Prio_D1
column for the error shown in the table row is blank, the error is
never recorded into
ASI_AFAR_D1
.
■
Otherwise, the
Prio_D1
column for the error shown in the table row indicates
the
ASI_AFAR_D1
recording priority, as follows. Let P_D1 be the
Prio_D1
column value for the error
E1
. Then:
Upon detection of the error
E1
, if
P_D1
>
ASI_AFAR_D1.CONTENTS
, the error
E1
is recorded into
ASI_AFAR_D1
and
ASI_AFAR_D1.CONTENTS
is set to
P_D1
.
Upon detection of the error
E1
, if
P_D1
≤
ASI_AFAR_D1.CONTENTS
, the error
E1
is not recorded into
ASI_AFAR_D1
and
ASI_AFAR_D1
is unchanged.
■
Prio_U2
column
— Indicates the
ASI_AFAR_U2
recording priority for each error
shown in the
row as follows:
[1]
Register name:
ASI_ASYNC_FAULT_STATUS
(
ASI_AFSR
)
[2]
ASI:
4C
16
[3]
VA:
00
16
[4]
Error checking:
None
[5]
Format & function:
See
[6]
Initial value at reset:
Hard POR: All fields in
ASI_AFSR
are set to 0.
Other resets: Values in
ASI_AFSR
are unchanged.