A.51 read state register, A.70 shutdown (vis i), Read state register 58 shutdown (vis i) 58 – FUJITSU Implementation Supplement Fujitsu SPARC64 V User Manual
Page 69
58
SPARC JPS1 Implementation Supplement: Fujitsu SPARC64 V • Release 1.0, 1 July 2002
describes prefetch variants implemented in SPARC64 V.
A.51
Read State Register
In SPARC64 V, an
RDPCR
instruction will generate a
privileged_action
exception if
PSTATE.PRIV
= 0 and
PCR.PRIV
= 1. If
PSTATE.PRIV
= 0 and
PCR.PRIV
= 0,
RDPCR
will not cause any access privilege violation exception (impl. dep. #250).
A.70
SHUTDOWN (VIS I)
In SPARC64 V,
SHUTDOWN
acts as a
NOP
in privileged mode (impl. dep. #206).
TABLE A-7
Prefetch Variants
fcn
Fetch to:
Status
Description
0
L1D
S
1
L2
S
2
L1D
M
3
L2
M
4
—
—
NOP
5-15
reserved (SPARC V9)
illegal_instruction
exception is signalled.
16-19
implementation
dependent.
NOP
20
L1D
S
If an access causes an mTLB miss,
fast_data_access_MMU_miss
exception is signalled.
21
L2
S
If an access causes an mTLB miss,
fast_data_access_MMU_miss
exception is signalled.
22
L1D
M
If an access causes an mTLB miss,
fast_data_access_MMU_miss
exception is signalled.
23
L2
M
If an access causes an mTLB miss,
fast_data_access_MMU_miss
exception is signalled.
24-31
implementation
dependent
NOP