Page 267
System Features
AXXESS
®
ADMINISTRATOR’S GUIDE – January 2004
Power Failure Capabilities
•
Realm: This field does not appear for Alarm messages. This two-character field indi-
cates the realm responsible for the message. The field will contain one of the following 
abbreviations:
— DB indicates that the message applies to the system database. These problems can 
often be fixed with appropriate database programming.
— HW indicates the messages concerns the system hardware. Typically these prob-
lems are corrected by adjusting or replacing the affected hardware.
— EG is indicative of a software error which will, most likely, require the intervention
or attention of an Inter-Tel software engineer.
•
Source: This field does not appear for Alarm messages. This two-character field indi-
cates the software source responsible for the message.
— CP indicates that Call Processing is the source
— OS refers to the Operating System
— SS refers to the System Software
— AL refers to a Voice Processor link
•
Text: The Text field holds a text message that identifies the particular fault indicated by 
the record. This field is at least 40 characters in length and may extend onto subsequent 
lines if necessary to present adequate information about the fault. The information 
printed on an additional line is preceded with the character “+” to indicate the continua-
tion.
•
Auxiliary: When necessary, additional information may be printed as part of a message 
on separate lines. This additional information is referred to as “auxiliary text.” To iden-
tify this text as pertaining to the previous message, each line is preceded with the 
“<“character.
POWER FAILURE CAPABILITIES
The Central Processor (CPU) Card contains relay contacts that can be used for power failure 
transfer which allows one or more single-line sets to select predetermined trunks in the event 
of a processor board failure or a power failure. Additional equipment is required.
CUSTOMIZED SYSTEM PROGRAMMING REPORTS
Customized system programming reports can be created through the database. The program-
mer can select the programming area to be reported and then select the information that will be 
included. When extension numbers are listed in a report, they can be sorted by name, extension 