beautypg.com

Honeywell MK VI User Manual

Page 32

background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

32

D. Position Slide Lock and Spring Clip onto connector.

E. Install Backshell Housing onto connector. The Ground wire (used for ESD discharge) is terminated with

shielded pigtails inside the backshell to the P2 connector.

F. Organize and dress wire exiting from the backshell, route Configuration Module wires in a coil. Install Cable

Clamp, do not tighten Cable Clamp screws.

G. Secure the Configuration Module to the connector using screws provided. Tighten Cable Clamp screws as

required.

CONFIGURATION MODULE ASSEMBLY

REQUIRED:

Two items as follows:
1.0

Connector (P2)

Positronic Ind. RD50F10JVLC-15 *

2.0

Configuration Module

Honeywell

700-1710-020

* This item may be available from Honeywell under Part No. (440-1233-001)

ITEM 2 DESCRIPTION:
Connector P2 (Positronic Ind. PN RD50F10JVLC-15) is a packaged kit consisting of the following parts:

1.1

Connector, 50 socket D-Sub

Qty - 1

1.2

Contacts, size 20 crimp

Qty - 50

1.3

Backshell housing

Qty - 1

1.4

Backshell plate

Qty - 1

1.5

Screws, Phillips CSK

Qty - 2

1.6

Spring Clip

Qty - 1

1.7

Slide Lock

Qty - 1

1.8

Screws, Slotted

Qty - 2

1.9

Cable Clamp

Qty - 1

This manual is related to the following products: