Longitudinal acceleration (331), Left body angle of attack (224), Right body angle of attack (225) – Honeywell MK VI User Manual
Page 288: Vor/ils frequency (034), Pfd mode select word (163)
Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET
288
6.2.43 Longitudinal Acceleration (331)
LONGITUDINAL ACCELERATION
Source: IOC
LABEL (Octal) 331
Units: g’s
Max. Range: +/-4.0 g’s
Approx. LSB: 0.000977 g’s
Data Bits: 17 to 28 = 12
+ = Forward
Sign Bit: 29
Pad Bits: 11 to 16
Transmit Interval (mSec): 10 to 20
Data Type: 2’s Complement Binary
SDI Bits: 9, 10
6.2.44 Left Body Angle of Attack (224)
Body Angle of Attack
Source: IOC
LABEL (Octal) 224
Units: degrees
Max. Range: +/-180 degrees
Approx. LSB: 0.0439 degrees
Data Bits: 17 to 28 = 12
+ = Nose Up
Sign Bit: 29
Pad Bits: 11 to 16
Transmit Interval (mSec): 50 to 100
Data Type: 2’s Complement Binary
SDI Bits: 9, 10
6.2.45 Right Body Angle of Attack (225)
Body Angle of Attack
Source: IOC
LABEL (Octal) 225
Units: degrees
Max. Range: +/-180 degrees
Approx. LSB: 0.0439 degrees
Data Bits: 17 to 28 = 12
+ = Nose Up
Sign Bit: 29
Pad Bits: 11 to 16
Transmit Interval (mSec): 50 to 100
Data Type: 2’s Complement Binary
SDI Bits: 9, 10
6.2.46 VOR/ILS Frequency (034)
VOR/ILS Frequency
Source: ARINC 710 ILS
LABEL (Octal) 034
Units: MHz
Max. Range: 108 - 117.95MHz
Approx. LSB: 10 kHz
Data Bits: See NOTE
+ = N/A
Sign Bit: N/A
Pad Bits: N/A
Transmit Interval (mSec): 167 to 333
Data Type: Binary Coded Decimal (BCD)
SDI Bits: 9, 10
NOTE: This input is used to indicate if the VOR/ILS receiver is tuned to an ILS frequency, or to a VOR frequency.
BIT #14 will be set to a ‘0’ for all VOR frequencies, and to a ‘1’ for all ILS frequencies, by the tuning information source.
6.2.47 PFD Mode Select Word (163)
PFD MODE SELECT WORD – Type 4
Source: PFD via IOC
LABEL (Octal) 163
Units: N/A
Max. Range: N/A
Approx. LSB: N/A
Data Bits: See NOTE 2 and 3
+ = N/A
Sign Bit: N/A
Pad Bits: N/A
Transmit Interval (mSec): See NOTE 1
Data Type: Discrete
SDI Bits: N/A
NOTE 1: Transmit Interval for data from PFD via IOC is 250 mSec Maximum.
NOTE 2: BITS 25 to 28 contain Binary Code for Displayed Data Source, as listed below.
NOTE 3: BITS 19/20 indicate MDA selection status and BIT 21 indicates DH selection status, as listed below.
PFD Mode Select Word
BIT NO.
DEFINITION
19, 20
MDA Display Selection
Bit 19
Bit 20
0
0
MDA not selected
1
0
MDA selected
X
1
Not used
21
DH Display Selection
0
DH Not Selected
1
DH Selected