4.2.3 DC Analog Inputs

Unless otherwise specified, Input Signal accuracy is 1% linearity +0.1% full scale offset.

4.2.3.1 Radio Altitude

Quantity

1

Input Impedance, each leg

> 83 K

Maximum Reverse Fault Current

< 200

µ

A

Signal Range

0 to 2500 feet

Input Voltage Range (V

RA

)

37.7V

V

RA

-2.5V

Conversion Range (V

C

)

29.7V

V

C

-0.4V

Input Filter

0.1 Second Low Pass,

±

10%

Broken Wire Detect

Input will be biased to less than -50 feet

Pin Assignment (Signal Mnemonic):

Signal (+)
Return (-)

J1-64
J1-45

(RALT_H)
(RALT_L)

4.2.3.2 Low Level Glideslope

Quantity

1

Input Impedance, each leg

> 2.5 M

Reverse Fault Current

< 6.2

µ

A

Signal Range

±

12 Dots

Input Voltage Range

±

0.9 VDC

Input Filter

0.1 Second Low Pass,

±

10%

Input Type

Differential

Common Mode Voltage Range (V

CM

)

11V

V

CM

-2V

Broken Wire Detect

Input will be biased less than -15 dots

Pin Assignment (Signal Mnemonic):

+Up, Below Beam, Fly Up
+Down, Above Beam, Fly Down

J1-65
J1-46

(GSDEV_H)
(GSDEV_L)

4.2.3.3 Localizer Deviation or Low Level Glideslope Validity

This input can be configured as either a low level glideslope valid, or as a localizer deviation input. Installations that only
have the low level validity signal for glideslope can not activate the analog localizer input. See section 5.3.9 for more
information.

Quantity

1

Input Impedance, each leg

> 2.5 M

Reverse Fault Current

< 6.2

µ

A

Input Filter

0.1 Second Low Pass,

±

10%

Input Type

Differential

Common Mode Voltage Range (V

CM

)

11V

V

CM

-2V

When used as a validity input:
Pin Assignment (Signal Mnemonic):

+ Flag
– Flag

J1-30
J1-10

(GS_VAL_H)
(GS_VAL_L)

Active Voltage Range (Logic True)

+160 to +840 mVDC

Inactive Voltage Range (Logic False)

0 to 50 mVDC

Broken Wire Detect

Input will be biased less than –1 VDC

When used as a localizer input:
Pin Assignment (Signal Mnemonic):

CRS DEV + Fly Right
CRS DEV + Fly Left

J1-30
J1-10

(LCDEV_H)
(LCDEV_L)

Signal Range

±

12 Dots

Input Voltage Range

±

0.9 VDC

Broken Wire Detect

Input will be biased less than -15 dots