Honeywell MK VI User Manual
Page 218
Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET
218
Table 5.3.6.1-235
Collins ProLine 4 (Non-Integrated)
Display Configuration Group 2
Function
Value
Reference section
Display Type
Collins ProLine 4
Sweep Type
Standard with +/-60 degree limit
Category 7, Options Select Group #1
TA&D Alternate Pop Up: False
TA&D Alternate Pop Up: True
Auto Pop Up
Pop Up On Caution or Warning
Never Pop Up
5.3.7
Category 7, Options Select Group #1
Peaks Enabled: False
Peaks Enabled: True
Peaks Mode
Peaks Off
Peaks On
5.3.7
Manual select
Anytime
Manual deselect
Anytime
Auto Range
No
Moving Marker
No
Overlay Page
Yes, “TERR” or Peaks Elevations located on upper left side of Terrain
image.
Display bus type
ARINC 453
DISPLAY BUS #1
453TX_1
CONNECT TO:
A = J1-58
B = J1-59
Terrain Display data to switching relay/Symbol Generator
4.2.13.2
7.2
DISPLAY BUS #2
453TX_2
CONNECT TO:
A = J1-56
B = J1-57
Terrain Display data to switching relay/Symbol Generator
4.2.13.2
7.2
Display Input Control Group 244
CHANNEL
429_422RX_1
CONNECT TO: IOC #1 Bus
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Range (Mode/Range Word)
Reference
6.2.21
Label
155
Sig. Bits
Discrete
Range
5-640NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
50
CHANNEL
429RX_3
CONNECT TO: IOC #2 Bus
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
1
B = J2-40
Data
Range (Mode/Range Word)
Reference
6.2.21
Label
155
Sig. Bits
Discrete
Range
5-640NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
50
CONN PIN #
REFERENCE NAME
PIN FUNCTION
Polarity/Configuration
J1-32
GND_DISC_12
Reference
4.2.7
6.6.18
Display Select Discrete #1
Type 1 (Momentary)
Gnd = Display Select Toggle
J1-31
GND_DISC_13
Reference
4.2.7
6.6.19
Display Select Discrete #2
Type 1 (Momentary)
Gnd = Display Select Toggle
Output 429 Bus Group 0
Channel
Pins
Comments
429TX_1 (Low Speed)
A = J2-43
B = J2-42
Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x
Integration Notes:
1. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input
channels. This prevents the EGPWS from reporting an external bus fault on the second channel.