Pitch synchro attitude, 3 wire synchro (11.8 vac ), Uncorrected barometric altitude (cic 02702) – Honeywell MK VI User Manual
Page 274
Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET
274
Signal Dynamic Range:
–100 to +3200 Feet
Signal Reasonable Range:
–30 to +2800 Feet
Signal Open Wire Threshold
–50 Feet
Reference Dynamic Range:
None
Reference Reasonable Range:
None
Scale:
RALT (ft) = 250 ft/VDC * Volts
in
Input Signal Connection:
(+) = J1-64, (–) = J1-45
Input Reference Connection:
None
AIC Name:
D1 (DC1)
External Validity Flag Connection:
J1-29
AIC LSB:
0.25 Feet
AIC Status Mask:
0000200C
External Validity Type:
Discrete Validity
6.1.12 Pitch Synchro Attitude, 3 Wire Synchro (11.8 VAC )
Data Item
Value
Signal Name:
Pitch Attitude, 3 Wire Synchro
AIC Algorithm:
3 Wire Synchro (11.8 VAC)
Signal Dynamic Range:
±90° Synchro Angle (15.5 VAC max)
Signal Reasonable Range:
±80° Synchro Angle
Signal Open Wire Threshold
None
Reference Dynamic Range:
None
Reference Reasonable Range:
None
Scale:
Pitch Angle (deg) = 1 deg/deg
Input Signal Connection:
(X) = J1-5, (Y) = J1-7, (Z) = J1-6
Input Reference Connection:
None
AIC Name:
S3 (Synchro #3)
External Validity Flag Connection:
J1-68 (Common Validity with Roll Attitude 6.1.15)
AIC FIFO LSB:
0.00549316
°
AIC Status Mask:
0000010F
External Validity Type:
Discrete Validity
6.1.13 Uncorrected Barometric Altitude (CIC 02702)
Data Item
Value
Signal Name:
Uncorrected Baro Altitude, DC Voltage
AIC Algorithm:
DC Absolute
Signal Dynamic Range:
–3713 to +62,017 Feet
Signal Reasonable Range:
–1000 to +40,000 Feet
Signal Open Wire Threshold
–3000 Feet
Reference Dynamic Range:
None
Reference Reasonable Range:
None
Scale:
Altitude (Feet) = 4100 Feet/VDC * Volts – 1000 Feet
Input Signal Connection:
(+) = J1-62, (–) = J1-43
AIC Name:
D2 (DC2)
Input Reference Connection:
None
External Validity Flag Connection:
J1-9
AIC LSB:
2 Feet
AIC Status Mask:
0000200F
External Validity Type:
Discrete Validity