CONTENTS

General ............................................................................... 3

Before Installation ............................................................. 3

Installation ......................................................................... 3

Wiring ................................................................................. 4

XL800 Series Power Consumption ................................ 5

I/O Modules ................................................................... 5

Description of the XCL8010AU

Controller Module ......... 7

Overview........................................................................ 7

Interfaces and Bus Connections .................................. 10

Technical Data............................................................. 10

System Data........................................................... 10

Operational Environment ....................................... 10

Smoke Control Configuration....................................... 10

Data File Set-Up .......................................................... 11

Panel Reset ................................................................. 11

Typical Power Limited Circuit for XL800 ...................... 11

Connecting Single Bus Controller Systems ................. 11

XCL8010AU, I/O Modules on Single Rail............... 12

Multiple Rails in Single Cabinet.............................. 12

LonWorks Bus I/O Modules in Separate Rooms .... 12

How to Connect Panel Bus and L

ON

W

ORKS

Bus Mixed

Controller Systems ...................................................... 12

Connecting I/O Modules......................................... 12

Connecting I/O Modules to the XCL8010AU.......... 12

Setting Address of Panel Bus I/O Modules .................. 13

Setting the I/O Bus Switch ........................................... 14

L

ON

W

ORKS

Bus Topologies.......................................... 14

C-Bus Topologies ........................................................ 14

Mounting/Dismounting Modules.................................... 14

Mounting/Dismounting Controller/Sockets ................... 15

Mounting Sockets................................................... 15

Connecting Sockets ............................................... 15

Dismounting Sockets ............................................. 16

Mounting/Dismounting Electronic Modules .................. 16

Mounting Electronic Modules ................................. 16

Dismounting Electronic Modules ............................ 17

Connecting via C-Bus .................................................. 17

Connecting to the Controller................................... 17

Setting the C-Bus Termination Switch.................... 17

Shielding ................................................................ 17

Connecting HMIs or Laptops........................................ 17

Connecting the XI582 Operator Interface ............... 17

Connecting Laptops (XL-Online/CARE) ................. 18

XCL8010AU Terminals........................................... 18

Features ....................................................................... 18

L

ON

W

ORKS

Interface and Terminals ....................... 18

L

ON

W

ORKS

Service LED and Button....................... 18

C-Bus Tx LED and Rx LED .................................... 19

Reset Button........................................................... 19

HMI Interface .......................................................... 19

Alarm and Power LEDs .......................................... 20

Watchdog Status .................................................... 20

Modem Interface..................................................... 20

I/O Bus Switch S2................................................... 20

C-Bus Termination Switch S1................................. 21

Memory .................................................................. 21

Description of the I/O Modules ....................................... 21

Common Features ....................................................... 21

Analog Input Modules .................................................. 22

Types of Analog Input Modules .............................. 22

Features ................................................................. 22

Terminals................................................................ 22

XFL821AU Connection Examples .......................... 23

Analog Output Modules................................................ 24

Types of Analog Output Modules ........................... 24

Features ................................................................. 24

Terminals................................................................ 24

Technical Data........................................................ 24

Modules with Manual Overrides ............................. 25

XFL822AU Connection Example ............................ 25

Synchronization Behavior of Analog Output Module
Configured as Floating Output................................ 25

Binary Input Modules ................................................... 26

Types of Binary Input Modules ............................... 26

Features ................................................................. 26

Terminals................................................................ 26

Technical Data........................................................ 26

Status LEDs............................................................ 27

XF823AU Connection Examples ............................ 27

Relay Output Modules.................................................. 28

Types of Relay Output Modules ............................. 28

Features ................................................................. 28

Terminals................................................................ 28

Permissible Loads .................................................. 29

Status LEDs with Manual Overrides ....................... 29

Connection Examples............................................. 30