New connector – Honeywell MK VI User Manual
Page 136

Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET
136
Signal Name –MK-VI GPWS (965-0686-001, -020)
Signal Type
Same
Conn/Pin
Signal Type
< IN Out >
Signal Name -MK-VI/MK VIII EGPWS (Enhanced)
NEW CONNECTOR
J3-01
PWR (L) >
SmartCable Power Return (GND)
J3-02
< Gdisc
PCMCIA Card Present
J3-03
< Data
EGPWS Monitor Port RS-232 (RCV)
J3-04
Data >
EGPWS Monitor Port RS-232 (XMT)
J3-05
J3-06
PWR (H) >
SmartCable Power (+5VDC)
J3-07
< Clock
SmartCable Serial Clock
J3-08
< Data
SmartCable Serial Input
J3-09
Data >
SmartCable Serial Output
J3-10
< Gdisc
SmartCable Serial Select
J3-11
< Gdisc
GSE present
J3-12
< GND
Ground
J3-13
< GND
Ground
J3-14
< GND
Ground
J3-15
GPS ANT
< RF
GPS COAX Connection