Honeywell MK VI User Manual
Page 222

Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET
222
Table 5.3.6.1-239
Collins FPI-9XX (Integrated) with binary Peaks
MK VIII Only
Display Configuration Group 244
Function
Value
Reference section
Display Type
Collins FPI-9xx with binary Peaks Elevations
Sweep Type
Fan
Category 7, Options Select Group #1
TA&D Alternate Pop Up: False
TA&D Alternate Pop Up: True
Auto Pop Up
Category 7 does not affect pop up logic. The display controls pop up,
therefore enable/disable of pop up is done via the display.
5.3.7
Category 7, Options Select Group #1
Peaks Enable: False
Peaks Enable: True
Peaks Mode
Peaks Off
Peaks On
5.3.7
Binary Peaks Elevations
Yes - Data passed by ARINC 429, Labels 011 and 012
Manual Select
Selection is controlled by display
Manual Deselect
Deselection is controlled by display
Auto Range
Yes (10 NM) controlled by display
Moving Marker
No
Overlay Page
No
Display bus type
ARINC 453
DISPLAY BUS #1
453TX_1
CONNECT TO:
A = J1-58
B = J1-59
Terrain Display data to switching relay/Symbol Generator #1
4.2.13.2
7.2
DISPLAY BUS #2
453TX_2
CONNECT TO:
A = J1-56
B = J1-57
Terrain Display data to switching relay/Symbol Generator #2
4.2.13.2
7.2
Display Input Control Group 253
CHANNEL
429_422RX_1
CONNECT TO: WX-IND Bus 1 out
Format: ARINC 429 (Low Speed)
Fault Designation: DISPLAY BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Range
Reference
6.2.20
Label
273
Sig. Bits
N/A
Range
5-320NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
100
CHANNEL
429RX_3
CONNECT TO: WX-IND Bus 2 out
Format: ARINC 429 (Low Speed)
Fault Designation: DISPLAY BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Range
Reference
6.2.20
Label
273
Sig. Bits
N/A
Range
5-320NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
100
Output 429 Bus Group 1
Channel
Pins
Comments
429TX_1 (Low Speed)
A = J2-43
B = J2-42
Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, 7.1.4.x, 7.1.5.x and 7.1.6.x
429TX_2 (Low Speed)
A = J2-26
B = J2-9
Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, 7.1.4.x, 7.1.5.x and 7.1.6.x
Integration Notes:
1. The EGPWS ARINC 429 Output Bus must be connected to the display.
2. The FPI-9xx, when not selected, will command the display range to 10 NM and “Pop Up” to Terrain mode if there is
a Terrain alert. The range does not change if Terrain Mode is already selected when there is a Terrain Alert.
3. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input
channels. This prevents the EGPWS from reporting an external bus fault on the second channel.