Rs-232 cable, Smart cable, Terrain database cards – Honeywell MK VI User Manual
Page 20: Flight history card, Accessories not supplied, Arinc 453 terrain display wiring
Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET
20
Bendix/King
071-04003-0002
Computer Mounting Tray
1
EA
405-0383-001
1.8.2 RS-232 Cab le
The MK VI/MK VIII EGPWS RS-232 Cable can be ordered using the following part numbers:
NOTE: The RS-232 Cable can be built by the Installer/Operator per the description in Section 4.4.2.
Vendor Name
Vendor P/N
Description
QTY UM
Honeywell P/N
Honeywell
704-2617-001
RS-232 Cable
1
EA
704-2617-001
1.8.3 Smart Cabl e
The MK VI/MK VIII EGPWS Smart Cable can be ordered using the following part numbers:
Vendor Name
Vendor P/N
Description
QTY UM
Honeywell P/N
Honeywell
951-0386-001
Smart Cable
1
EA
951-0386-001
1.8.4 Terrain Dat abase Cards
The MK VI EGPWS Terrain Database Cards can be ordered using the following part numbers:
Vendor Name
Vendor P/N
Description
QTY UM
Honeywell P/N
Honeywell
718-1391-xxx
North & South America
1
EA
718-1391-xxx
Honeywell
718-1392-xxx
Europe, Africa, Asia
1
EA
718-1392-xxx
Honeywell
718-1393-xxx
Asia, Australia, Pacific
1
EA
718-1393-xxx
Honeywell
402-6075-xxx
Label, TDB Front Panel
1
EA
402-6075-xxx
1.8.5 Flight Histo ry Card
The MK VI/MK VIII EGPWS Flight History Card can be ordered using the following part numbers:
Vendor Name
Vendor P/N
Description
QTY UM
Honeywell P/N
Honeywell
Honeywell
300-1151-006
1
718-1593-001
2
Flight History Download
Flight History Download
1
1
EA
EA
300-1151-006
1
718-1593-001
Note 1: Unprogrammed (blank) 32 Mb card ATA PCMCIA card.
Note 2: Programmed 32 Mb card ATA PCMCIA card.
1.9 Accessorie s not Supplied
1.9.1 ARINC 453 Terrain Display wiring
The Terrain display wiring (ARINC 453) must meet the display manufacturer’s specifications including
termination method. ARINC 453 bus wiring must meet the following requirements:
•
Cable length must be less than 300 feet (91.4 meters).
•
Wire to wire capacitance must not exceed 50 pF/foot.
•
Shielded twisted pair with not less than one twist per inch.
•
Impedance of 78 ohms ±10% at 1 MHz (ARINC 708 WXR).
•
Impedance of 70 ohms ±10% at 1 MHz (ARINC 453 bus).
Vendor Name
Vendor P/N
Description
QTY UM
Pic Wire&Cable
D620224
ARINC 453 cable
A/R
EA