Rs-232 cable, Smart cable, Terrain database cards – Honeywell MK VI User Manual

Page 20: Flight history card, Accessories not supplied, Arinc 453 terrain display wiring

background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

20

Bendix/King

071-04003-0002

Computer Mounting Tray

1

EA

405-0383-001

1.8.2 RS-232 Cab le

The MK VI/MK VIII EGPWS RS-232 Cable can be ordered using the following part numbers:

NOTE: The RS-232 Cable can be built by the Installer/Operator per the description in Section 4.4.2.

Vendor Name

Vendor P/N

Description

QTY UM

Honeywell P/N

Honeywell

704-2617-001

RS-232 Cable

1

EA

704-2617-001

1.8.3 Smart Cabl e

The MK VI/MK VIII EGPWS Smart Cable can be ordered using the following part numbers:
Vendor Name

Vendor P/N

Description

QTY UM

Honeywell P/N

Honeywell

951-0386-001

Smart Cable

1

EA

951-0386-001

1.8.4 Terrain Dat abase Cards

The MK VI EGPWS Terrain Database Cards can be ordered using the following part numbers:
Vendor Name

Vendor P/N

Description

QTY UM

Honeywell P/N

Honeywell

718-1391-xxx

North & South America

1

EA

718-1391-xxx

Honeywell

718-1392-xxx

Europe, Africa, Asia

1

EA

718-1392-xxx

Honeywell

718-1393-xxx

Asia, Australia, Pacific

1

EA

718-1393-xxx

Honeywell

402-6075-xxx

Label, TDB Front Panel

1

EA

402-6075-xxx

1.8.5 Flight Histo ry Card

The MK VI/MK VIII EGPWS Flight History Card can be ordered using the following part numbers:
Vendor Name

Vendor P/N

Description

QTY UM

Honeywell P/N

Honeywell
Honeywell

300-1151-006

1

718-1593-001

2

Flight History Download
Flight History Download

1
1

EA
EA

300-1151-006

1

718-1593-001

Note 1: Unprogrammed (blank) 32 Mb card ATA PCMCIA card.
Note 2: Programmed 32 Mb card ATA PCMCIA card.

1.9 Accessorie s not Supplied

1.9.1 ARINC 453 Terrain Display wiring

The Terrain display wiring (ARINC 453) must meet the display manufacturer’s specifications including
termination method. ARINC 453 bus wiring must meet the following requirements:

Cable length must be less than 300 feet (91.4 meters).

Wire to wire capacitance must not exceed 50 pF/foot.

Shielded twisted pair with not less than one twist per inch.

Impedance of 78 ohms ±10% at 1 MHz (ARINC 708 WXR).

Impedance of 70 ohms ±10% at 1 MHz (ARINC 453 bus).

Vendor Name

Vendor P/N

Description

QTY UM

Pic Wire&Cable

D620224

ARINC 453 cable

A/R

EA