7.1.6.2 Peaks Lower Elevation (012)

Data: See Below

Label (Octal): 012

Transmit Interval: 500 msec

±

10%

BIT NO DEFINITION

9

SDI

0 Not Used

1 Captain

0 F/O

1 Not Used

10

SDI

0

0

1

1

11

COLOR BIT 1

0

1

0

1

0

1

0

1

12

COLOR BIT 2

0 Black

0 Green

1 Yellow

1 Red

0 Magenta 0 Blue

1 Cyan

1 White

13

COLOR BIT 3

0

0

0

0

1

1

1

1

14

BLANK PEAKS ELEVATION DISPLAY

0 Normal Display

1 Blank Display

15

DASH PEAKS ELEVATION DISPLAY

0 Normal Display

1 Display Dashes

16

SPARE

17

SPARE

18

SPARE

19

SPARE

20

100 Ft

21

200 Ft

22

400 Ft

23

800 Ft

24

1600 Ft

Lower Peaks Elevation

25

3200 Ft

26

6400 Ft

27

12800 Ft

28

25600 Ft

NOTE: Elevation bits are
additive; e.g., bits 20 & 21 = 1
indicates 300 Ft.

29

SIGN

0 = 0 (Plus)

1 = - 51200 Ft

30

SSM

0 Failure

1 No Computed

0 Functional Test

1 Normal

31

SSM

0 Warning

0 Data

1

1 Operation

32

PARITY (Odd)

7.2 ARINC 708A Output

Two channels of ARINC 708A or KCPB (453) data is provided to drive terrain displays for installations that use the
Terrain Awareness display function. Refer to document 060-4303-000, EGPWS Interface Methodology for further KCPB
information. See Category 6 for more details on individual displays.

7.3 Audio

Output

Mode computation outputs generally result in an audio voice alert unless inputs are invalid or one of the audio suppression
discretes is active. The actual output message, or intended message during audio suppression, is sent to the alert lamp
logic for proper output activation.

The audio outputs consist of an 8 ohm amplifier and a transformer isolated 600 ohm output. Additional automatic volume
control lowers both outputs a fixed 6 dB below the nominal level on command. Refer to section 4.2.12 and Category 14
for information on volume levels.

Selectable sets of voice alert messages can be defined. Each set is selected by the Voice Menu option in Category 5.

7.4 Discrete

Outputs

Outputs from the various alert mode computations are first processed to determine which lamp outputs to produce. All of
the lamp outputs are driven by solid state switches to ground. These outputs can also be used as discrete drivers for other
devices. All monitor lamp outputs are normally a steady state switch to ground. Various formats of discrete outputs can be
provided as defined in Category 13.

7.4.1 Ground Proximity Alerts Discrete (Lamp) Outputs

Two Lamp formats are defined as a function of the selected I/O Discrete Type of section 5.3.13. For Lamp Format type 1,
only Mode 5 “Glideslope” message will activate the alert lamp output (amber). All other messages will activate the
warning lamp output (red). Note that Mode 6 does not activate any lamp outputs, only voices.

With Lamp Format 2, only the messages containing the phrase “Pull Up” will activate the warning lamp output (red). All
other messages will activate the alert lamp output (amber).

The Glideslope Cancel Input Discrete controls the output of the Mode 5 “Glideslope” message. If the Glideslope Cancel
Input Discrete is activated then the caution lamp (amber) and the voice annunciation will be inhibited for the Mode 5
“Glideslope” message.