MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

185

TABLE 5.3.2-12: AIR DATA INPUT SELECT #12

SIGNAL

CONNECTION

REFERENCE

SUMMARY DATA

Uncorrected Barometric
Altitude

(+) = J1-62
(–) = J1-43

6.1.16

Format: DC with Validity Flag
Input Type: Basic
Fault Designation: BAROMETRIC ALTITUDE FAULT
Validity: Barometric Alt Valid (+28V)

Outside Air Temp

No Connection

N/A

No temperature

Computed Airspeed

No Connection

N/A

Substitute Ground Speed for Airspeed (airspeed is not available with this air data
input)

PIN FUNCTION

CONNECTION

PIN TYPE

CHANNEL

DESIGNATION

REFERENCE

Polarity/Configuration

References

Barometric Altitude
Validity Discrete (+28V)

J1-9

Input

28V_DISC_08

>+17V = Valid
< +4.4V = Invalid

6.6.22
4.2.7

Configuration Data

Type

Summary Data

Derive Baro Altitude Rate

Analog

Baro Altitude Rate is derived using
Uncorrected Barometric Altitude.
Although the ADC’s provide Baro Rate,
the EGPWS does not have an analog
connection available.

TABLE 5.3.2-13: AIR DATA INPUT SELECT #13

CHANNEL
429RX_2

CONNECT TO: ADC #1
Format: ARINC 429 (Low Speed)

Fault Designation: AIR DATA BUS
Bus Type: Basic

A = J2-39
B = J2-38

Data
Uncorrected Baro. Alt

Reference
6.2.1

Label
203

Sig. Bits
17

Range
±131,072 FT

Signal Type
Basic

Resolution
1.0

Rate (ms)
31.3-62.5

Outside Air Temp

No Connection

N/A

No temperature

Computed Airspeed

No Connection

N/A

Substitute Ground Speed for Airspeed (airspeed is not available with this air data
input)

Configuration Data

Type

Summary Data

Derive Baro Altitude Rate

Digital

Baro Altitude Rate is derived using
Uncorrected Barometric Altitude.
Baro Rate is not available with this air
data source.