beautypg.com

Category 12, windshear input select, 12 category 12, windshear input select, Table 5.3.12: windshear input select – Honeywell MK VI User Manual

Page 257

background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

257

5.3.12 Category 12, Windshear Input Select

The following table provides identification of the Windshear Input Type. The entry in the Windshear Input Type
corresponds to a table that provides detailed information on the configuration. For example, the details for Windshear
Input Type #255 are found in 5.3.12-255.

In this category, only the following signals are to be defined:

Body Angle of Attack (AOA) in ARINC 429 format

Normalized Angle of Attack (AOA) in ARINC 429 format

Table 5.3.12: Windshear Input Select

ID

Windshear

Input Type

Description

Windshear

Disable

Windshear

INOP

Windshear

Caution

Windshear

Caution Voice

Software

Effectivity

EGPWS

Effectivity

Disable

Disable

Disable

MKVI

MKVIII

0

N/A

No Windshear

TRUE

TRUE

TRUE

TRUE

-020

X

X

253

255

Digital – ARINC 429
AOA (via Dual IOC
buses). (Note 1)

FALSE

FALSE

TRUE

TRUE

-020

N/A

X

254

255

Digital – ARINC 429
AOA (via Dual IOC
buses). (Note 1)

FALSE

FALSE

FALSE

TRUE

-020

N/A

X

255

255

Digital – ARINC 429
AOA (via Dual IOC
buses). (Note 1)

FALSE

FALSE

FALSE

FALSE

-020

N/A

X

Note 1: IDs 253, 254, and 255 may only be used in conjunction with other IOC bus selections for categories 2, 6, 8, 9, 10,
and 11.

Table 5.3.12-255: Windshear Input Type 255

CHANNEL

429RX_1

CONNECT TO: IOC #1 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 1
Bus Type: Basic

A = J2-37
B = J2-36

Data

Left Angle of Attack Body

Normal Angle of Attack

Reference

6.2.44
6.2.52

Label

224
236

Sig. Bits

12
15

Range

±180 degrees

0 to 1

Signal Type

Basic
Basic

Resolution

0.0439453125 deg

0.00003051757812

Rate (ms)

100

80

CHANNEL

429RX_3

CONNECT TO: IOC #2 Bus
Format: ARINC 429 (High Speed)

Fault Designation: IOC BUS 2
Bus Type: Basic

A = J2-41
B = J2-40

Data

Right Angle of Attack Body

Normal Angle of Attack

Reference

6.2.45
6.2.52

Label

225
236

Sig. Bits

12
15

Range

±180 degrees

0 to 1

Signal Type

Basic
Basic

Resolution

0.0439453125 deg

0.00003051757812

Rate (ms)

100

80

This manual is related to the following products: