MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET
231
Table 5.3.6.1-248
Honeywell Primus 1000
MK VIII Only
Display Configuration Group 248
Function
Value
Reference section
Display Type
Honeywell Primus 1000
Sweep Type
Honeywell
Category 7, Options Select Group #1
TA&D Alternate Pop Up: False
TA&D Alternate Pop Up: True
Auto Pop Up
Pop Up On Caution or Warning
Never Pop Up
5.3.7
Category 7, Options Select Group #1
Peaks Enable: False
Peaks Enable: True
Peaks Mode
Peaks Off
Peaks On
5.3.7
Manual select
Selection is controlled by display
Manual deselect
Deselection is controlled by display
Auto Range
Yes 10NM
Moving Marker
Yes (Honeywell type)
Overlay Page
Yes, for Peaks Elevations only (located middle right side of the display)
Display bus type
Honeywell picture bus
DISPLAY BUS #1 & #2
453TX_1
CONNECT TO:
A = J1-58
B = J1-59
Terrain Display data to switching relay/Symbol Generator
4.2.13.2
7.2
CONNECT TO:
Not supported for this display type
Display Input Control Group 248
CHANNEL
429_422RX_1
CONNECT TO: IC600 #1 FDR Bus
Format: ARINC 429 (High Speed)
Fault Designation: FDR BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Range
Discrete Word
Reference
6.2.23
6.2.28
Label
050
275
Sig. Bits
Bits 11-14
Bit 17
Range
2000NM
Discrete
Signal Type
Basic
Basic
Resolution
N/A
N/A
Rate (ms)
100
500
CHANNEL
429RX_3
CONNECT TO: IC600 #2 FDR Bus
Format: ARINC 429 (High Speed)
Fault Designation: FDR BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Range
Discrete Word
Reference
6.2.23
6.2.28
Label
050
275
Sig. Bits
Bits 11-14
Bit 17
Range
2000NM
Discrete
Signal Type
Basic
Basic
Resolution
N/A
N/A
Rate (ms)
100
500
Output 429 Bus Group 0
Channel
Pins
Comments
429TX_1 (Low Speed)
A = J2-43
B = J2-42
Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x
Integration Notes:
1. The EGPWS ARINC 429 Output Bus must be connected to the display.
2.
Display channels 1 and 2 are multiplexed on ARINC 453 bus 1.
3.
The system only has one range for terrain display on MFD, therefore the range to use depends on the value of label
275, bit 17.
8. The Terrain display will Pop-Up in response to EGPWS label 274, bit 28 (Left display) and bit 29 (right display).
9. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input
channels. This prevents the EGPWS from reporting an external bus fault on the second channel.
10. This configuration will cause the GPWS INOP, TERRAIN INOP, and WINDSHEAR INOP lamps to turn on only at
the beginning of the EGPWS Self Test.