beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 500

background image

500

Touch Probe Cycles: Automatic Kinematics Measurement

1

8

.5 PRESET COMPENSA

TION (Cy

c

le 452, DIN/ISO:

G452, Option)

4

The TNC automatically measures all the rotary axes successively
in the resolution you defined. The current measurement status is
displayed in a pop-up window. The TNC hides the status window
when the distance to be traversed is greater than the radius of the
ball tip.

5

Use Cycle 452 for preset compensation at regular intervals. The
TNC measures the drift of the axes involved and compensates it in
the kinematics description.

Parameter number

Meaning

Q141

Standard deviation measured in the A axis
(–1 if axis was not measured)

Q142

Standard deviation measured in the B axis
(–1 if axis was not measured)

Q143

Standard deviation measured in the C axis
(–1 if axis was not measured)

Q144

Optimized standard deviation in the A axis
(–1 if axis was not measured)

Q145

Optimized standard deviation in the B axis
(–1 if axis was not measured)

Q146

Optimized standard deviation in the C axis
(–1 if axis was not measured)

Q147

Offset error in X direction, for manual
transfer to the corresponding machine
parameter

Q148

Offset error in Y direction, for manual
transfer to the corresponding machine
parameter

Q149

Offset error in Z direction, for manual
transfer to the corresponding machine
parameter