HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual
Page 364

364
Touch Probe Cycles: Automatic Datum Setting
15.2 SL
O
T
CENTER REF PT (Cy
c
le
408, DIN/ISO:
G408, FCL
3
F
u
nction)
Probe in TS axis
Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0: Do not set the datum in the touch probe axis
1: Set the datum in the touch probe axis
Probe TS axis: Coord. 1st axis
Q382 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range -99999.9999 to 99999.9999
Probe TS axis: Coord. 2nd axis
Q383 (absolute):
Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1. Input
range -99999.9999 to 99999.9999
Probe TS axis: Coord. 3rd axis
Q384 (absolute):
Coordinate of the probe point in the touch probe axis,
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1. Input range
-99999.9999 to 99999.9999
New datum in TS axis
Q333 (absolute): Coordinate in
the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range -99999.9999
to 99999.9999
Beispiel: NC blocks
5 TCH PROBE 408 SLOT CENTER REF PT
Q321=+50
;CENTER IN 1ST AXIS
Q322=+50
;CENTER IN 2ND AXIS
Q311=25
;SLOT WIDTH
Q272=1
;MEASURING AXIS
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q305=10
;NO. IN TABLE
Q405=+0
;DATUM
Q303=+1
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+1
;DATUM