Cycle run

Touch Probe Cycle 9 automatically calibrates the length of a touch
trigger probe at a point that you determine.

1

Pre-position the touch probe so that the touch probe axis
coordinate defined in the cycle can be accessed without collision.

2

The TNC moves the touch probe in the direction of the negative
tool axis until a trigger signal is released.

3

Finally, the TNC moves the touch probe back to the starting point
of the probing process and writes the effective touch probe length
to the calibration data.

Cycle parameters

Coordinate of datum

(absolute): Exact coordinate of

the point that is to be probed. Input range
-99999.9999 to 99999.9999

Reference system? (0=ACT/1=REF)

: Specify the

coordinate system on which the entered datum is to
be based:
0: Entered datum is based on the active workpiece
coordinate system (ACT system)
1: Entered datum is based on the active machine
coordinate system (REF system)

Beispiel: NC blocks

5 L X-235 Y+356 R0 FMAX

6 TCH PROBE 9.0 CALIBRATE TS LENGTH

7 TCH PROBE 9.1 DATUM +50 REFERENCE