beautypg.com

Please note while programming, Cycle parameters – HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 394

background image

394

Touch Probe Cycles: Automatic Datum Setting

15.1

0

D

A

TUM CIR

C

LE CENTER (Cy

c

le

416, DIN/ISO:

G416)

Please note while programming:

Cycle parameters

Center in 1st axis

Q273 (absolute): Bolt-hole circle

center (nominal value) in the reference axis of the
working plane. Input range -99999.9999 to
99999.9999

Center in 2nd axis

Q274 (absolute): Bolt-hole circle

center (nominal value) in the minor axis of the working
plane. Input range -99999.9999 to 99999.9999

Nominal diameter

Q262: Enter the approximate bolt-

hole circle diameter. The smaller the hole diameter,
the more exact the nominal diameter must be. Input
range 0 to 99999.9999

Angle of 1st hole

Q291 (absolute): Polar coordinate

angle of the first hole center in the working plane.
Input range -360.0000 to 360.0000

Angle of 2nd hole

Q292 (absolute): Polar coordinate

angle of the second hole center in the working plane.
Input range -360.0000 to 360.0000

Angle of 3rd hole

Q293 (absolute): Polar coordinate

angle of the third hole center in the working plane.
Input range -360.0000 to 360.0000

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made. Input range
-99999.9999 to 99999.9999

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999; alternatively PREDEF

Number in table

Q305: Enter the number in the

datum/preset table in which the TNC is to save the
coordinates of the bolt-hole circle center. If you enter
Q305=0 and Q303=1, the TNC automatically sets the
display so that the new datum is on the bolt-hole
circle center. If you enter Q305=0 and Q303=0, the
TNC writes the bolt-hole circle center in line 0 of the
datum table. Input range 0 to 99999

New datum for reference axis

Q331 (absolute):

Coordinate in the reference axis at which the TNC
should set the bolt-hole circle center. Default setting
= 0. Input range -99999.9999 to 99999.9999

Before a cycle definition you must have programmed a
tool call to define the touch probe axis.

X

Y

Q274

Q273

Q262

Q291

Q293

Q292

X

Y