431

16.6 MEA

S

URE CIR

C

LE OUTSIDE (Cy

c

le 422, DIN/ISO:

G422)

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Create measuring log: By default, the TNC saves
the log file TCHPR422.TXT in the directory in which
your measuring program is stored.
2: Interrupt program run and display the measuring
log on the screen. Resume program run with NC
Start.

PGM stop if tolerance error

Q309: Definition of

whether in the event of a violation of tolerance limits
the TNC is to interrupt program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message

Tool for monitoring

Q330: Definition of whether the

TNC is to monitor the tool (siehe „Tool monitoring”
auf Seite 416). Inp
ut range: 0 to 32767.9, alternatively
tool name with max. 16 characters
0: Monitoring not active
>0: Tool number in the tool table TOOL.T

No. of measuring points (4/3)

Q423: Specify

whether the TNC should measure the stud with 4 or
3 probing points:
4: Use 4 measuring points (default setting)
3: Use 3 measuring points

Type of traverse? Line=0/Arc=1

Q365: Definition of

the path function with which the touch probe is to
move between the measuring points if "traversing to
clearance height" (Q301=1) is active:
0: Move in a straight line between measuring points
1: Move in a circular arc between measuring points

Beispiel: NC blocks

5 TCH PROBE 422 MEAS. CIRCLE OUTSIDE

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+90

;STARTING ANGLE

Q247=+30

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+10

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q277=35.15 ;MAX. LIMIT

Q278=34.9 ;MIN. LIMIT

Q279=0.05 ;TOLERANCE 1ST CENTER

Q280=0.05 ;TOLERANCE 2ND CENTER

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL

Q423=4

;NO. OF MEAS. POINTS

Q365=1

;TYPE OF TRAVERSE