Touch Probe Cycles: Automatic Workpiece Inspection
16.9 MEA
S
URE INSIDE WIDTH (Cy
c
le 425, DIN/ISO:
G425)
Measuring log
Q281: Definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Create measuring log: By default, the TNC saves
the log file TCHPR425.TXT in the directory in which
your measuring program is stored.
2: Interrupt program run and display the measuring
log on the screen. Resume program run with NC
Start.
PGM stop if tolerance error
Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
Tool for monitoring
Q330: Definition of whether the
TNC is to monitor the tool (siehe „Tool monitoring”
auf Seite 416). Input range: 0 to 32767.9, alternatively
tool name with max. 16 characters
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999;
alternatively PREDEF
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternative: PREDEF
Beispiel: NC blocks
5 TCH PROBE 425 MEASURE INSIDE WIDTH
Q328=+75
;STARTING POINT 1ST AXIS
Q329=-12.5 ;STARTING POINT 2ND AXIS
Q310=+0
;OFFS. 2ND MEASUREMENT
Q272=1
;MEASURING AXIS
Q261=-5
;MEASURING HEIGHT
Q260=+10
;CLEARANCE HEIGHT
Q311=25
;NOMINAL LENGTH
Q288=25.05 ;MAX. LIMIT
Q289=25
;MIN. LIMIT
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP IF ERROR
Q330=0
;TOOL
Q320=0
;SET-UP CLEARANCE
Q301=0
;MOVE TO CLEARANCE