HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual
Page 355

HEIDENHAIN iTNC 530
355
14.7 Compensating w
o
rk
piece misalignment b
y
r
o
tating the C axis (Cy
c
le
405, DIN/ISO:
G405)
Measuring height in the touch probe axis
Q261
(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999;
alternatively PREDEF
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999; alternatively PREDEF
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternative: PREDEF
Set to zero after alignment
Q337: Definition of
whether the TNC should set the display of the C axis
to zero, or write the angular misalignment in column
C of the datum table:
0: Set the display of the C axis to zero and write the
value in line 0 of the datum table
>0:Write the measured angular misalignment with
correct algebraic signs in the datum table. Line
number = value of Q337. If a C-axis shift is registered
in the datum table, the TNC adds the measured
angular misalignment.
Beispiel: NC blocks
5 TCH PROBE 405 ROT IN C AXIS
Q321=+50
;CENTER IN 1ST AXIS
Q322=+50
;CENTER IN 2ND AXIS
Q262=10
;NOMINAL DIAMETER
Q325=+0
;STARTING ANGLE
Q247=90
;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q337=0
;SET TO ZERO
X
Z
Q261
Q260
MP6140
+
Q320