beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 350

background image

350

Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment

14.5 BA

SIC R

O

T

A

TION compensation via r

o

tary axis (Cy

c

le 403,

DIN/ISO:

G403)

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999; alternatively PREDEF

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points

Axis for compensation motion

Q312: Assignment of

the rotary axis in which the TNC is to compensate the
measured misalignment.
0: Automatic mode – the TNC uses the active
kinematics to determine the rotary axis to be aligned.
In automatic mode the first rotary table axis (as
viewed from the workpiece) is used as compensation
axis. Recommended setting.
4: Compensate misalignment with rotary axis A
5: Compensate misalignment with rotary axis B
6: Compensate misalignment with rotary axis C

Set to zero after alignment

Q337: Definition of

whether the TNC should set the display of the aligned
rotary axis to zero:
0: Do not reset the display of the rotary axis to 0 after
alignment
1: Reset the display of the rotary axis to 0 after
alignment

Number in table

Q305: Enter the number in the

preset table/datum table in which the TNC is to set
the rotary axis to zero. Only effective if Q337 is set to
1. Input range 0 to 99999

Measured-value transfer (0, 1)

Q303: Specify

whether the determined angle is to be saved in the
datum table or in the preset table:
0: Write the measured angle as a datum shift in the
active datum table. The reference system is the
active workpiece coordinate system.
1: Write the measured angle in the preset table. The
reference system is the machine coordinate system
(REF system).

Reference angle? (0=ref. axis)

Q380: Angle with

which the TNC is to align the probed straight line.
Only effective if rotary axis = automatic mode is
selected, or rotary axis = C is selected (Q312 = 0 or
6). Input range -360.000 to 360.000

Beispiel: NC blocks

5 TCH PROBE 403 ROT IN C-AXIS

Q263=+25

;1ST POINT 1ST AXIS

Q264=+10

;1ST POINT 2ND AXIS

Q265=+40

;2ND POINT 1ST AXIS

Q266=+17

;2ND POINT 2ND AXIS

Q272=2

;MEASURING AXIS

Q267=+1

;TRAVERSE DIRECTION

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q312=0

;COMPENSATION AXIS

Q337=0

;SET TO ZERO

Q305=1

;NO. IN TABLE

Q303=+1

;MEAS. VALUE TRANSFER

Q380=+0

;REFERENCE ANGLE