HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual
Page 483

HEIDENHAIN iTNC 530
483
1
8
.4 MEA
S
URE KINEMA
TICS (Cy
c
le 451, DIN/ISO:
G451; Option)
4
The TNC automatically measures all the rotary axes successively
in the resolution you defined. The current measurement status is
displayed in a pop-up window. The TNC hides the status window
when the distance to be traversed is greater than the radius of the
ball tip.
5
The TNC saves the measured values in the following Q
parameters:
Parameter number
Meaning
Q141
Standard deviation measured in the A axis
(–1 if axis was not measured)
Q142
Standard deviation measured in the B axis
(–1 if axis was not measured)
Q143
Standard deviation measured in the C axis
(–1 if axis was not measured)
Q144
Optimized standard deviation in the A axis
(–1 if axis was not optimized)
Q145
Optimized standard deviation in the B axis
(–1 if axis was not optimized)
Q146
Optimized standard deviation in the C axis
(–1 if axis was not optimized)
Q147
Offset error in X direction, for manual
transfer to the corresponding machine
parameter
Q148
Offset error in Y direction, for manual
transfer to the corresponding machine
parameter
Q149
Offset error in Z direction, for manual
transfer to the corresponding machine
parameter