beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 483

background image

HEIDENHAIN iTNC 530

483

1

8

.4 MEA

S

URE KINEMA

TICS (Cy

c

le 451, DIN/ISO:

G451; Option)

4

The TNC automatically measures all the rotary axes successively
in the resolution you defined. The current measurement status is
displayed in a pop-up window. The TNC hides the status window
when the distance to be traversed is greater than the radius of the
ball tip.

5

The TNC saves the measured values in the following Q
parameters:

Parameter number

Meaning

Q141

Standard deviation measured in the A axis
(–1 if axis was not measured)

Q142

Standard deviation measured in the B axis
(–1 if axis was not measured)

Q143

Standard deviation measured in the C axis
(–1 if axis was not measured)

Q144

Optimized standard deviation in the A axis
(–1 if axis was not optimized)

Q145

Optimized standard deviation in the B axis
(–1 if axis was not optimized)

Q146

Optimized standard deviation in the C axis
(–1 if axis was not optimized)

Q147

Offset error in X direction, for manual
transfer to the corresponding machine
parameter

Q148

Offset error in Y direction, for manual
transfer to the corresponding machine
parameter

Q149

Offset error in Z direction, for manual
transfer to the corresponding machine
parameter