HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual
Page 363

HEIDENHAIN iTNC 530
363
15.2 SL
O
T
CENTER REF PT (Cy
c
le
408, DIN/ISO:
G408, FCL
3
F
u
nction)
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternative: PREDEF
Number in table
Q305: Enter the number in the
datum/preset table in which the TNC is to save the
coordinates of the slot center. If you enter Q305=0
and Q303=1, the TNC automatically sets the display
so that the new datum is on the slot center. If you
enter Q305=0 and Q303=0, the TNC writes the slot
center in line 0 of the datum table. Input range 0 to
99999
New datum
Q405 (absolute): Coordinate in the
measuring axis at which the TNC should set the
calculated slot center. Default setting = 0. Input range
-99999.9999 to 99999.9999
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).