beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 363

background image

HEIDENHAIN iTNC 530

363

15.2 SL

O

T

CENTER REF PT (Cy

c

le

408, DIN/ISO:

G408, FCL

3

F

u

nction)

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternative: PREDEF

Number in table

Q305: Enter the number in the

datum/preset table in which the TNC is to save the
coordinates of the slot center. If you enter Q305=0
and Q303=1, the TNC automatically sets the display
so that the new datum is on the slot center. If you
enter Q305=0 and Q303=0, the TNC writes the slot
center in line 0 of the datum table. Input range 0 to
99999

New datum

Q405 (absolute): Coordinate in the

measuring axis at which the TNC should set the
calculated slot center. Default setting = 0. Input range
-99999.9999 to 99999.9999

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the
datum table or in the preset table:
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).