beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 383

background image

HEIDENHAIN iTNC 530

383

15.7 D

A

TUM FR

OM OUTSIDE OF CIR

C

LE (Cy

c

le 413, DIN/ISO:

G413)

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set the datum in the touch probe axis
1: Set the datum in the touch probe axis

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range -99999.9999 to 99999.9999

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1. Input
range -99999.9999 to 99999.9999

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1. Input range
-99999.9999 to 99999.9999

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the
datum. Default setting = 0

No. of measuring points (4/3)

Q423: Specify

whether the TNC should measure the stud with 4 or
3 probing points:
4: Use 4 measuring points (default setting)
3: Use 3 measuring points

Type of traverse? Line=0/Arc=1

Q365: Definition of

the path function with which the touch probe is to
move between the measuring points if "traversing to
clearance height" (Q301=1) is active.
0: Move in a straight line between measuring points
1: Move in a circular arc between measuring points

Beispiel: NC blocks

5 TCH PROBE 413 DATUM OUTSIDE CIRCLE

Q321=+50

;CENTER IN 1ST AXIS

Q322=+50

;CENTER IN 2ND AXIS

Q262=75

;NOMINAL DIAMETER

Q325=+0

;STARTING ANGLE

Q247=+60

;STEPPING ANGLE

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q305=15

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Q423=4

;NO. OF MEAS. POINTS

Q365=1

;TYPE OF TRAVERSE