beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 396

background image

396

Touch Probe Cycles: Automatic Datum Setting

15.1

0

D

A

TUM CIR

C

LE CENTER (Cy

c

le

416, DIN/ISO:

G416)

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis,
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1. Input range
-99999.9999 to 99999.9999

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range -99999.9999
to 99999.9999

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140, and is only effective when the
datum is probed in the touch probe axis. Input range
0 to 99999.9999; alternatively PREDEF