beautypg.com

Cycle parameters, 4 mea s uring (cy c le 3) – HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 466

background image

466

Touch Probe Cycles: Special Functions

1

7.4 MEA

S

URING (Cy

c

le 3)

Cycle parameters

Parameter number for result

: Enter the number of

the Q parameter to which you want the TNC to assign
the first measured coordinate (X). The values Y and Z
are in the immediately following Q parameters. Input
range: 0 to 1999

Probing axis

: Enter the axis in whose direction the

probe is to move and confirm with the ENT key. Input
range: X, Y or Z

Probing angle

: Angle, measured from the defined

probing axis

, in which the touch probe is to move.

Confirm with ENT. Input range –180.0000 to
180.0000

Maximum measuring range

: Enter the maximum

distance from the starting point by which the touch
probe is to move. Confirm with ENT. Input range
-99999.9999 to 99999.9999

Feed rate for measurement

: Enter the measuring

feed rate in mm/min. Input range 0 to 3000.000

Maximum retraction distance

: Traverse path in the

direction opposite the probing direction, after the
stylus was deflected. The TNC returns the touch
probe to a point no farther than the starting point, so
that there can be no collision. Input range 0 to
99999.9999

Reference system? (0=ACT/1=REF)

: Specify whether

the probing direction and the result of measurement
are to be referenced to the actual coordinate system
(ACT, can be shifted or rotated), or to the machine
coordinate system (REF):
0: Probe in the current system and save
measurement result in the ACT system
1: Probe in the machine-based REF system and save
measurement result in the REF system

Error mode (0=OFF/1=ON)

: Specify whether the TNC

is to issue an error message if the stylus is deflected
at cycle start. If mode 1 is selected, the TNC saves
the value 2.0 in the 4th result parameter and
continues the cycle:
0: Issue error message
1: Do not issue error message

Beispiel: NC blocks

4 TCH PROBE 3.0 MEASURING

5 TCH PROBE 3.1 Q1

6 TCH PROBE 3.2 X ANGLE: +15

7 TCH PROBE 3.3 DIST +10 F100 MB1

REFERENCE SYSTEM:0

8 TCH PROBE 3.4 ERRORMODE1