HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual
Page 492

492
Touch Probe Cycles: Automatic Kinematics Measurement
1
8
.4 MEA
S
URE KINEMA
TICS (Cy
c
le 451, DIN/ISO:
G451; Option)
Feed rate for pre-positioning
Q253: Traversing
speed of the tool in mm/min during positioning. Input
range 0.0001 to 99999.9999; alternatively FMAX,
FAUTO
, PREDEF
Reference angle
Q380 (absolute): Reference angle
(basic rotation) for measuring the measuring points in
the active workpiece coordinate system. Defining a
reference angle can considerably enlarge the
measuring range of an axis. Input range 0 to 360.0000
Start angle A axis
Q411 (absolute): Starting angle in
the A axis at which the first measurement is to be
made. Input range -359.999 to 359.999
End angle A axis
Q412 (absolute): Ending angle in the
A axis at which the last measurement is to be made.
Input range -359.999 to 359.999
Angle of incid. A axis
Q413: Angle of incidence in
the A axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999
Number meas. points A axis
Q414: Number of probe
measurements with which the TNC is to measure the
A axis. If the input value = 0, the TNC does not
measure the respective axis. Input range 0 to 12
Start angle B axis
Q415 (absolute): Starting angle in
the B axis at which the first measurement is to be
made. Input range -359.999 to 359.999
End angle B axis
Q416 (absolute): Ending angle in the
B axis at which the last measurement is to be made.
Input range -359.999 to 359.999
Angle of incid. in B axis
Q417: Angle of incidence
in the B axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999
Number meas. points B axis
Q418: Number of probe
measurements with which the TNC is to measure the
B axis. If the input value = 0, the TNC does not
measure the respective axis. Input range 0 to 12