beautypg.com

Cycle parameters, 5 mea s uring in 3-d (cy c le 4, fcl 3 function) – HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 468

background image

468

Touch Probe Cycles: Special Functions

1

7.5 MEA

S

URING IN 3-D (Cy

c

le 4, FCL

3

function)

Cycle parameters

Parameter number for result

: Enter the number of

the Q parameter to which you want the TNC to assign
the first coordinate (X). Input range 0 to 1999

Relative measuring path in X

: X component of the

direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999

Relative measuring path in Y

: Y component of the

direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999

Relative measuring path in Z

: Z component of the

direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999

Maximum measuring path

: Enter the maximum

distance from the starting point by which the touch
probe may move along the direction vector. Input
range -99999.9999 to 99999.9999

Feed rate for measurement

: Enter the measuring

feed rate in mm/min. Input range 0 to 3000.000

Maximum retraction distance

: Traverse path in the

direction opposite the probing direction, after the
stylus was deflected. Input range 0 to 99999.9999

Reference system? (0=ACT/1=REF)

: Specify whether

the result of measurement is to be saved in the actual
coordinate system (ACT, can be shifted or rotated), or
with respect to the machine coordinate system (REF).
0: Save the measurement result in the ACT system
1: Save the measurement result in the REF system

Beispiel: NC blocks

5 TCH PROBE 4.0 MEASURING IN 3-D

6 TCH PROBE 4.1 Q1

7 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1

8 TCH PROBE
4.3 DIST +45 F100 MB50 REFERENCE SYSTEM:0