Cycle parameters – HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual
Page 475

HEIDENHAIN iTNC 530
475
1
7.8 CALIBRA
TE TS (Cy
c
le 460, DIN/ISO:
G460)
Cycle parameters
Exact calibration sphere radius
Q407: Enter the
exact radius of the calibration sphere used. Input
range 0.0001 to 99.9999
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999;
alternatively PREDEF
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternative: PREDEF
No. of probe points in plane (4/3)
Q423: Specify
whether the TNC should measure the calibration
sphere in the plane with 4 or 3 probing points. 3
probing points increase the measuring speed:
4: Use 4 measuring points (default setting)
3: Use 3 measuring points
Reference angle
Q380 (absolute): Reference angle
(basic rotation) for measuring the measuring points in
the active workpiece coordinate system. Defining a
reference angle can considerably enlarge the
measuring range of an axis. Input range 0 to 360.0000
Calibrate length (0/1)
Q433: Define whether the
TNC should also calibrate the touch probe length after
radius calibration:
0: Do not calibrate touch probe length
1: Calibrate touch probe length
Datum for length
Q434 (absolute): Coordinate of the
calibration sphere center. The definition is only
required if length calibration is to be carried out. Input
range -99999.9999 to 99999.9999
Beispiel: NC blocks
5 TCH PROBE 460 CALIBRATE TS
Q407=12.5 ;SPHERE RADIUS
Q320=0
;SET-UP CLEARANCE
Q301=1
;MOVE TO CLEARANCE
Q423=4
;NO. OF PROBE POINTS
Q380=+0
;REFERENCE ANGLE
Q433=0
;CALIBRATE LENGTH
Q434=-2.5 ;DATUM