beautypg.com

6 set basic rotation (cycle 404, din/iso: g404), Cycle run, Cycle parameters – HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 351: Seite 351

background image

HEIDENHAIN iTNC 530

351

14.6 SET BA

SIC R

O

T

A

TION (Cy

c

le

404, DIN/ISO:

G404)

14.6 SET BASIC ROTATION

(Cycle 404, DIN/ISO: G404)

Cycle run

With Touch Probe Cycle 404, you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.

Cycle parameters

Preset value for basic rotation

: Angular value at

which the basic rotation is to be set. Input range -
360.000 to 360.000

Number in table

Q305: Enter the number in the

preset/datum table in which the TNC is to save the
defined basic rotation.
-1: The TNC overwrites the active datum and
activates it.
0: The TNC copies the active datum to the datum 0,
writes the basic rotation, and activates the datum 0.
>0:The TNC merely writes the defined basic rotation
to the specified datum number and does not activate
this datum. Use Cycle 247, if necessary (siehe
„DATUM SETTING (Cycle 247, DIN/ISO: G247)” auf
Seite 286)
Input range 0 to 99999

Beispiel: NC blocks

5 TCH PROBE 404 BASIC ROTATION

Q307=+0

;PRESET BASIC ROTATION

Q305=1

;NO. IN TABLE