beautypg.com

HEIDENHAIN iTNC 530 (60642x-04) Cycle programming User Manual

Page 456

background image

456

Touch Probe Cycles: Automatic Workpiece Inspection

16.13 MEA

S

URE PLANE (Cy

c

le 431, DIN/ISO:

G431)

Set-up clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999;
alternatively PREDEF

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999; alternatively PREDEF

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Create measuring log: By default, the TNC saves
the log file TCHPR431.TXT in the directory in which
your measuring program is stored.
2: Interrupt program run and display the measuring
log on the screen. Resume program run with NC
Start.

Beispiel: NC blocks

5 TCH PROBE 431 MEASURE PLANE

Q263=+20

;1ST POINT 1ST AXIS

Q264=+20

;1ST POINT 2ND AXIS

Q294=+10

;1ST POINT 3RD AXIS

Q265=+90

;2ND POINT 1ST AXIS

Q266=+25

;2ND POINT 2ND AXIS

Q295=+15

;2ND POINT 3RD AXIS

Q296=+50

;3RD POINT 1ST AXIS

Q297=+80

;3RD POINT 2ND AXIS

Q298=+20

;3RD POINT 3RD AXIS

Q320=0

;SET-UP CLEARANCE

Q260=+5

;CLEARANCE HEIGHT

Q281=1

;MEASURING LOG