Organization mode of operation

8.2

Pa

ra

met

ers

General settings

:

Parameter: System / ...

Meaning

... / Definition of the units of measure valid for the display (101100)

/ ...

... / Unit of measure for display and user interface (101101)

metric

Use the metric system

inch

Use the inch system

... / General settings for automatic operation (601800) / ...

.../ Service life management (601801)

ON

Tool life monitoring is active

OFF

Tool life monitoring is inactive

.../ End mid-program startup after start block (601810)

TRUE

In mid-program startup, program execution begins

with the subsequent NC block

FALSE

In mid-program startup, program execution begins

with the selected NC block

... / Tool measurement (604600)

Measuring feed rate [mm/min] (604602)

Feed rate for approaching the touch probe

Measuring range [mm] (604603)

The touch probe must be triggered within the

measuring range. Otherwise, an error message is

issued.