Environmental criteria – Grass Valley PVS Series System Guide v.4.0 Dec 10 200 User Manual
Page 257

Environmental Criteria
July 27, 2001
Profile XP System Guide
257
Environmental Criteria
The following table lists the environmental criteria for the Profile XP Media Platform,
PFC500, and the PAC216.
Characteristics
Description
Operating Temperature
Requirement:
10
°
to 40
°
C
Storage Temperature
Requirement:
-40
°
to 65
°
C
Operating Altitude
Requirement:
To 10,000 feet
Supplemental Data:
IEC 950 compliant to 2000 meters
Storage Altitude
Requirement:
To 40,000 feet
Mechanical Shock
Supplemental Data: Class 5 (30G) Tektronix 062-2858-00 RevB
Random Vibration
Requirement:
Operational: Class 6 Tektronix 062-2858-00 RevB
Requirement:
Non-Operational: Class 5 Tektronix 062-2858-00
RevB
Transportation
Requirement:
Tektronix 062-9527-00
Equipment Type
Supplemental Data:
Information Technology
Equipment Class
Supplemental Data:
Class 1
Installation Category
Requirement:
Category II Local level mains, appliances, portable
equipment, etc.
Pollution Degree
Requirement:
Level 2 operating environment, indoor use only.
Relative Humidity
Requirement:
Operating 80% from +30
°
to +40
°
C
Non-Operating 90% from +30
°
to +60
°
C
Do not operate with visible moisture on the circuit
boards