Reference Genlock
LTC Timecode
GPI I/O
Characteristics
Description
Color Field Detection, Based on
SCH Phase
Requirement:
Correct color framing for signals having an
average SCH phase
±
40
°
; Lockup
±
10
°
Supplemental Data:
Once locked to color field, it will stay locked
over a range of 0
°
to
±
90
°
Burst Frequency Lock Range
Requirement:
PAL,
±
10 Hz at subcarrier
NTSC,
±
20 Hz at subcarrier
Signal Amplitude Lock Range
Requirement:
Stays locked to +6 dB and -3 dB
Reference Genlock Input Return
Loss
Requirement:
≥
40 dB to 5 MHz
Characteristics
Description
Input
Supplemental Data:
Longitudinal Time Code. AC coupled,
differential input
Input Impedance
Supplemental Data:
20 k
Ω
.
Input Amplitude
Supplemental Data:
0.1 V p-p, differential, minimum
Maximum Input Voltage
Supplemental Data:
2.5 V p-p, differential, maximum
Characteristics
Description
GPI Input
Supplemental Data:
Inputs set to TTL level high.
Compatible with 5 volts CMOS/TTL open
collector or contact closures.
GPI Output
Supplemental Data:
Outputs are open drain drivers.
Max. voltage when outputs are open = 30V