Deleting unwanted vitc signals – Grass Valley PVS Series System Guide v.4.0 Dec 10 200 User Manual
Page 185

Deleting unwanted VITC signals
July 27, 2001
Profile XP System Guide
185
Deleting unwanted VITC signals
You can remove unwanted VITC signals that may be present in a recorded video clip
or on the output during E to E by selecting which VBI lines to erase. You can erase
VBI lines by selecting the range of line numbers between line 1 to line 32. Blanking
level is inserted in place of the VBI information. Lines are erased before VITC
timecode is inserted.
To erase VITC lines:
1. Choose Video Output in the Configuration Manager Window. The Video Output
dialog box appears.
2. Click
Next
to navigate to Video Output page 2 of 3.
3. Select a video output from the list or click
Select All
to configure all the video
outputs at the same time.