Timecode options, Timecode source, Timecode status – Grass Valley Imagestore 750 v.2.0.1 User Manual
Page 178: Intuition set, Def keyer assign

Front Panel Operations
Imagestore 750 User Manual
Page 178
Miranda Technologies Inc.
Timecode Options
When physically connected, the LTC or VITC timecode source is used to
adjust the internal clock once per minute. When a timecode source is not
connected, the internal clock will be free running. The internal clock is also
available as an Easytext data source.
Timecode Source
Allows you to select between LTC or VITC as a timecode source.
Timecode Status
Displays the LTC or VITC timecode on the front panel display.
Intuition Set
This menu configures the Imagestore 750 when used in conjunction with an
Imagestore Intuition advanced channel branding system.
Refer to the Graphics Co-processor section on page 241.
Def Keyer Assign
This option enables Automatic Keyer Management which sets the selected
keying layer for Intuition control. When the Intuition keyer is cut up the
Imagestore 750 will perform a ‘Load Live’ on that layer and display the
composited stream. As additional Intuition layers are cut up the Imagestore
will continue to display the composited stream.
None
No Automatic Keyer Management set. Imagestore will ignore the Intuition
output.
DSK1
Automatic Keyer Management enabled on DSK1.