Gpi channels, Create a gpi macro – Grass Valley Imagestore 750 v.2.0.1 User Manual
Page 134

Front Panel Operations
Imagestore 750 User Manual
Page 134
Miranda Technologies Inc.
GPI Channels
GPI
Signal name
Type
GPI Pin No
44-way
GPI Pin No
25-way
1
GPI1
IN/OUT
42
25
2
GPI2
IN/OUT
12
12
3
GPI3
IN/OUT
41
24
4
GPI4
IN/OUT
11
11
5
GPI5
IN/OUT
40
23
6
GPI6
IN/OUT
10
10
7
GPI7
IN/OUT
39
22
8
GPI8
IN/OUT
9
9
9
GPI9
IN/OUT
38
21
10
GPI10
IN/OUT
36
19
11
GPI11
IN/OUT
6
6
12
GPI12
IN/OUT
35
18
13
GPI13
IN/OUT
5
5
14
GPI14
IN/OUT
34
17
15
GPI15
IN/OUT
4
4
16
GPI16
IN/OUT
33
16
GND
GND
GND
13, 32
13, 15
Create a GPI Macro
To create a macro, display the relevant GPI then press enter. If the GPI is
unused >Empty< will be displayed on the front panel.
Press enter again to gain access to the entire Imagestore 750 Operate
menu.
Using the joystick arrows ⊳ display the first command to be added to the
macro and press enter to add it. The display is now returned to the listing of
the macro, showing the added command. To add a second command, use the
joystick arrows ⊳ to display the next command and press enter as before.
Further commands are added to the macro using the same procedure.