Matrix module leds, Matrix module leds are identified in table 59 – Grass Valley Concerto Routing Matrix v.1.8.1 User Manual
Page 158

158
Concerto — Installation and Service Manual
Section 5 — Maintenance and Troubleshooting
Matrix Module LEDs
Matrix Module LEDs are identified in
.
Table 59. Matrix Modules LEDs
Analog &
Digital
Audio
Analog
Video
Digital
HD & SD
Video
Time Code
Port
LEDs
Label
Indication
Condition
DIAG
(red)
On
Diagnostic (factory use)
Off
Normal
OVER TEMP
(red)
On
Over temperature
a
a
Check air intake and exhaust temperature, fans and air filter. Verify chassis ventilation slots are clear and door is closed.
Off
Normal
PARITY ERROR
(red)
On
Parity error
Off
Normal
ERROR
(red)
On
Error.
Off
Normal
BSY or BUSY
(yellow)
On
Busy
b
b
Signifies that a switch has been activated.
Off
Standby
POWER OK or
PWR OK
(green)
On
Power on
Off
Bad or unseated module
DONE
(green)
On
Done
Off
FPGA loaded, module ready
AVI 1
(green)
On
Audio reference 1 present
Off
No reference 1
AVI 2
(green)
On
Audio reference 2 present
Off
No reference 2
VI 1
(green)
On
Video Reference 1 present
Off
No reference 1
VI 2
(green)
On
Video Reference 2 present
Off
No reference 2
AES REF
(green)
On
AES reference present
Off
No AES reference
LOOP LOCKED
(green)
On
Locked to AES reference
Off
No lock to AES reference
BOARD ENABLE or
BRD ENABLE
(green)
On
Module is communicating with
the Controller module
c
c
Flashing indicates receiving communication.
for 3Gb/s module LEDs
Off
Module is not communicating
with the Controller module
OVER
TEMP
DIAG
POWER
OK
ERROR
BUSY
P
ARITY
ERROR
DONE
A
VI 2
A
VI 1
AES
REF
LOOP
LOCKED
BOARD
ENABLE
PWR
OK
DONE
ERROR
BUSY
A
VI 2
A
VI 1
P
ARITY
ERROR
OVER
TEMP
DIAG
BRD
ENABLE
POWER
OK
DONE
ERROR
BUSY
VI 2
VI 1
P
ARITY
ERROR
OVER
TEMP
DIAG
BOARD
ENABLE
OVER
TEMP
DIAG
POWER
OK
ERROR
BUSY
P
ARITY
ERROR
DONE
BOARD
ENABLE