beautypg.com

Maintenance and troubleshooting, Field replaceable units, Modules – Grass Valley Concerto Routing Matrix v.1.8.1 User Manual

Page 145: To remove modules, To insert modules, Section 5 — maintenance and troubleshooting

background image

Concerto — Installation and Service Manual

145

Section

5

Maintenance and
Troubleshooting

Field Replaceable Units

Modules and Power Supplies are not serviced in the field. Replace faulty
modules and Power Supplies with spares. Return faulty units to a desig-
nated repair depot. Use the information located on the back of the title page
to contact Customer Service.

The fan assembly can be replaced by a complete new assembly. The filter
slides in and out of the frame for cleaning or replacement.

Modules

Modules can be inserted or removed from the frame without powering
down the system.

To Remove Modules

1.

Lift the ejector tabs on the front of the module.

2.

Pull the module gently to disengage it from the backplane.

3.

Slide the module out of the frame.

4.

Use anti-static precautions to protect the module.

To Insert Modules

1.

Align the module in the appropriate frame slot.

2.

Slide the module into the frame.

3.

Gently push the module to engage the backplane.