If the setting for this switch is On:

The Controller in CMS1 will take control as Master, or

If the Controller in CMS1 fails, the Controller module in CMS2 will
take over, or

If the Controller in CMS1 is reset, the Controller module in CMS2
will take over until the Controller in CMS1 reboots at which time
the Controller in CMS1 will take control, or

If there is only one Controller module and it is in CMS2, it will be
Master, or

If there is one Controller module in CMS2, and a second Controller
module is seated and booted in CMS1, the Controller module in
CMS1 will take control.

If the setting for this switch is Off:

When there are two Controller modules, whichever one boots the
fastest will be the Master, or

If there is only one Controller module and it is in either Controller
module slot it will be the Master.

6.

Set Level and Options for each slot.

Banks S2, S3, S4, S5, S7, S8, S9, and S10 are used to assign Levels and
Options to the module slots. DIP Switch number 8 is not used on banks
S4, S7, or S8.

Table 49

shows which banks and setting types are used for

each slot.

Table 50

shows the common default level settings used by matrices in

the Jupiter Control System. You can set any of the 127 possible levels;
for the complete set see

Appendix B-Reference Tables

. The common levels

shown are the ones supported by Concerto.

Table 49. DIP Switch Bank and Module Slot Number

Module Slot #

DIP Switch Bank

Setting Type

1

S2

Level

S3

Options

2

S4

Level

S5

Options

3

S7

Level

S8

Options

4

S9

Level

S10

Options