Table 57 – Grass Valley Concerto Routing Matrix v.1.8.1 User Manual
Page 156

156
Concerto — Installation and Service Manual
Section 5 — Maintenance and Troubleshooting
The LEDs found on the 10/100Base-T Matrix Controller module are shown
in
Table 57. 10/100Base-T Matrix Controller LEDs
Group
Label
LED
Indication
Condition
Ethernet
FAST
D8
(yellow)
On
Ethernet active at 100Base-T
Off
Ethernet inactive
COL
D9
(red)
On
Ethernet collision
Off
No collision
RX
D10
(green)
On
Ethernet receiving
Off
Not receiving
TX
D11
(green)
On
Ethernet transmitting
Off
Not transmitting
LINK
D12
(green)
On
Ethernet connected
Off
No Ethernet connection
Reference
SYNC
ERR
D13
(red)
On
AES Reference error
Off
Normal
VI2
PRES
D14
(green)
On
Video Reference 2 present
Off
Not present
VI1
PRES
D15
(green)
On
Video Reference 1 present
Off
Not present
TC PRES
D16
(green)
On
Time code present
Off
Not present
48K
PRES
D17
(green)
On
AES Present
a
a
Valid AES Reference generated from top Audio module distributed through matrix.
Off
Not present
Activity and
Power
ACTIVE
D1
(yellow)
On
Normal - active control
b
b
Controller module is in control of matrix.
Off
Standby
RECV
D2
(green)
On
External com-receiving
Off
Not receiving
XMIT
D3
(green)
On
External com-transmitting
Off
Not transmitting
ERROR
D4
(red)
On
Circuit failure or reset
c
c
Alarm conditions are; fan or power supply failure, TDM error, or Controller module reset.
Off
Normal
BUSY
D5
(yellow)
On
Active Controller indication
d
d
Flashing indicates receiving communication from control system.
Off
Inactive
PWR
D6
(green)
On
Chassis power at proper voltage
Off
Bad or unseated module
DONE
D7
(green)
On
FPGA loaded, module ready
Off
Module not functional
PWR
DONE
ACTIVE
T P 1
GND
+5V
+3.3V
ERROR
TC
PRES
BUSY
48K
PRES
LINK
SYNC
ERR
RECV
VI 2
PRES
XMIT
VI 1
PRES
CLEAR MEM
RESET
Yellow
Green
Red
Legend
TX
RX
FAST
COL
T P 2
T P 3