Field Replaceable Units

Figure 82. Fan Replacement (7 RU frame shown)

Controller Modules

Swapping a MCS-MC-C2 with a MCS-MC-C2

The following procedures are used to swap a MCS-MC-C2 with a replace-
ment.

Encore Controlled Non-Redundant Systems

1.

Inspect the new Controller module.

2.

Set the DIP Switch bank S11 switch number 1 to

ON

. Switches 2 to 8 are

set to

OFF

.

3.

Remove the old Controller module.

4.

Insert and seat the new Controller module.

The

PWR OK

(power OK) and

DONE

LED will light signifying the module

is up and ready to receive commands. The next command sent from the
control system will cause the

ACT

(active) LED to turn on.

The next command sent from the control system will cause the

ACT

LED

to turn on. Continued commands prompt the

ACT

LED to flash.

5.

Send a switch command from the control system and verify that the
switch was executed.

8138_00_09r0

Fan Module