beautypg.com

Grass Valley Concerto Routing Matrix v.1.8.1 User Manual

Page 157

background image

Concerto — Installation and Service Manual

157

Troubleshooting

The LEDs found on the 10Base-T Matrix Controller module are shown in

Table 58

.

Table 58. 10Base-T Matrix Controller LEDs

Group

Label

LED

Indication

Condition

Activity and

Power

ACTIVE

D1

(yellow)

On

Normal - active control

a

a

Controller module is in control of matrix.

Off

Standby

ETR

LINK/

ACT

D2

(green)

On

Ethernet-link

Off

No Ethernet-link

RECV

D4

(yellow)

On

External com-receiving

Off

Not receiving

XMIT

D6

(green)

On

External com-transmitting

Off

Not transmitting

ERR

D8

(red)

On

Circuit failure or reset

b

b

Alarm conditions are; fan or power supply failure, TDM error, or Controller module reset.

Off

Normal

BSY

D10

(yellow)

On

Active Controller indication

c

c

Flashing indicates receiving communication from control system.

Off

Inactive

PWR

D12

(green)

On

Chassis power at proper voltage

Off

Bad or unseated module

DONE

D14

(green)

On

FPGA loaded, module ready

Off

Module not functional

Reference

SYNC

ERR

D3

(red)

On

AES Reference error

Off

Normal

VI2

PRES

D5

(green)

On

Video Reference 2 present

Off

Not present

VI1

PRES

D7

(green)

On

Video Reference 1 present

Off

Not present

TC PRES

D9

(green)

On

Time code present

Off

Not present

48K

PRES

D11

(green)

On

AES Present

d

d

Valid AES Reference generated from top Audio module distributed through matrix.

Off

Not present

PWR

DONE

ACTIVE

LINK/ACT

TP2

GND

TP4

+5V

+3.3V

TP7

TP20

+2.5V

ERROR

TC

PRES

BUSY

48K

PRES

ETR

SYNC

ERR

RECV

VI 2

PRES

XMIT

VI 1

PRES

CLEAR

MEM

RESET

Yellow

Green

Red

Legend