beautypg.com

Verifying the configuration – H3C Technologies H3C S5830V2 Series Switches User Manual

Page 96

background image

85

[SwitchB-Vfc1] bind interface ten-gigabitethernet 1/0/1

# Assign VFC 1 to VSAN 2 as a trunk port.

[SwitchB-Vfc1] port trunk vsan 2

[SwitchB-Vfc1] quit

# Configure Ten-GigabitEthernet 1/0/1 as a trunk port, and assign the port to VLAN 10.

[SwitchB] interface ten-gigabitethernet 1/0/1

[SwitchB-Ten-GigabitEthernet1/0/1] port link-type trunk

[SwitchB-Ten-GigabitEthernet1/0/1] port trunk permit vlan 10

[SwitchB-Ten-GigabitEthernet1/0/1] quit

# Enable FCoE for VLAN 10, and map VLAN 10 to VSAN 2.

[SwitchB] vlan 10

[SwitchB-vlan10] fcoe enable vsan 2

[SwitchB-vlan10] quit

# Enable FSPF for VFC 1.

[SwitchB] interface vfc 1

[SwitchB-Vfc1] undo fspf silent vsan 2

[SwitchB-Vfc1] quit

Verifying the configuration

# Display the FSPF neighbor information for Switch A.

[SwitchA] display fspf neighbor

FSPF neighbor information of VSAN 2(01):

Interface NbrDomain IfIndex NbrIfIndex Dead Time State

Vfc1 2 0x68 0x68 00:01:06 Full

# Display the routing table information for Switch A.

[SwitchA] display fc routing-table vsan 2

Routing Table: VSAN 2

Destinations : 5 Routes : 5

Destination/mask Protocol Preference Cost Interface

0x020000/8 FSPF 20 100 Vfc1

0xfffc01/24 DIRECT 0 0 InLoop0

0xfffffa/24 DIRECT 0 0 InLoop0

0xfffffc/24 DIRECT 0 0 InLoop0

0xfffffd/24 DIRECT 0 0 InLoop0

# On Switch A, use the fcping command to ping Switch B and identify whether Switch B is

reachable.

[SwitchA] fcping fcid fffc02 vsan 2

FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break.

Reply from 0xfffc02: bytes = 128 time = 1.102 ms

Reply from 0xfffc02: bytes = 128 time = 0.276 ms

Reply from 0xfffc02: bytes = 128 time = 0.253 ms

Reply from 0xfffc02: bytes = 128 time = 0.270 ms

Reply from 0xfffc02: bytes = 128 time = 0.247 ms

--- 0xfffc02 fcping statistics ---

5 packet(s) transmitted

5 packet(s) received